Page 84 - Green Pin Product Catalog
P. 84
FOR WIRE ROPE Instructions for use
When chain fittings with a safety factor of 4 : 1 are used in combination with steel wire rope the WLL
must be reduced by 20 %. This is the difference between a design factor of 4 : 1 (for chain slings) and
5 : 1 (for steel wire rope slings).
See table below:
(t)
(t)
4 : 1 Working Load Limit 5 : 1 Minimum Breaking Load
Safety factor Safety factor
LIFTING SLING FITTINGS
1.12 0.896 4.48
1.25 1 5
1.6 1.28 6.4
2 1.6 8
2.5 2 10
3.2 2.56 12.8
3.5 2.8 14
3.65 2.92 14.6
4.5 3.6 18
5.4 4.32 21.6
6.2 4.96 24.8
6.5 5.2 26
6.8 5.44 27.2
8.2 6.56 32.8
8.5 6.8 34
10 8 40
10.6 8.48 42.4
11 8.8 44
11.2 8.96 44.8
11.5 9.2 46
3 .1 12.8 10.24 51.2
13 10.4 52
15.5 12.4 62
16 12.8 64
17 13.6 68
17.7 14.16 70.8
20 16 80
20.8 16.64 83.2
21.2 16.96 84.8
21.6 17.28 86.4
22 17.6 88
25 20 100
27.6 22.08 110.4
30 24 120
31.5 25.2 126
32.8 26.24 131.2
37 29.6 148
40 32 160
41.6 33.28 166.4
50 40 200
60 48 240
63 50.4 252
80 64 320
100 80 400
125 100 500
84