Page 127 - Green Pin Product Catalogue 2019_EN
P. 127
Instructions for use
Connecting links, master links and master link assemblies should be inspected before use to ensure that: LINKS
• all markings are legible;
• the link and the assemblies are both made of the same steel grade;
• a link with the correct WLL has been selected with respect to the sling design. For further details,
refer to the EN 818 standard for Chain Slings;
• the pin, bush or any other locking system cannot move or vibrate out of position;
• links, assemblies and connecting links are free from nicks, gouges and cracks;
• links, assemblies and connecting links are not heat treated (this may affect their Working Load Limit);
• all components of the sling are of the same steel grade;
• items are not distorted or unduly worn.
Also:
• only use the items for in-line lifting;
• never modify, repair or reshape an item by machining, welding, heating or bending, as this may affect
the WLL.
Master links, master link assemblies and connecting links must be regularly inspected in accordance with
the safety standards given in the country of use. This is required because the products in use may be
affected by issues such as wear, misuse and overloading, which may lead to deformation and alteration of
the material structure. Inspection should take place at least every six months, and more frequently when
the links are used in severe operating conditions.
7